An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN that is now configured with an EMC Symmetrix subsystem disk. The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()
第1题:
The customer is considering an IBM System Storage DS8000. Which of the following indicates a requirement for the Business Partner to perform a TDA?()
第2题:
A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment. What is the best solution()
第3题:
A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()
第4题:
A customer currently buys HP ProLiant servers and EMC storage. The customer has encountered various problems getting certain servers to work with their storage. Which of the following arguments can the Sales Specialist present to best position IBM? ()
第5题:
A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()
第6题:
A customer with an EMC Clariion CX700 storage installation is considering a new IBM TotalStorage DS4500 solution. Which of the following is an advantage of the IBM DS4500 solution?()
第7题:
A customer recently installed new SAN with an IBM System Storage DS8300 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment. What is the best solution()
第8题:
A customer has a mission-critical application with redundant fabrics. The customer plans to replace older EMC Symmetrix 8830 systems with an IBM System Storage DS8700 and an IBM SAN Volume Controller (SVC). Which statement best describes the way to minimize the impact of data migration on the production environment()
第9题:
IBM System Storage DS8000: Host Systems Attachment Guide
DS8000 Interoperability Matrix
IBM System Storage DS8000: Introduction and Planning Guide
IBM System Storage Solution Handbook
第10题:
purchasing customer
IBM Installation Readiness Team
IBM Customer Engineer
IBM Business Partner
第11题:
The EMC storage specialist has not participated in the TDA meeting
The FC HBAs are 4 Gbps technology
The Technical and Delivery Assessment review actions were not executed
The customer should have checked that the HBAs are supported according to the HP storage interoperability matrix
第12题:
2
4
6
8
第13题:
A customer has recently purchased some IBM x445 servers running Red Hat Enterprise AS 3 and wants to connect them to their existing EMC Clarion SAN controller. Which of the following steps must be taken in order to validate the solution?()
第14题:
A customer wants to integrate an x445 running SuSE with their existing EMC storage infrastructure. Which of the following tasks needs to be done to ensure that the solution will work properly?()
第15题:
A customer has an EMC Symmetrix DMX-4 installed. The disk subsystem is coming off lease. The customer is considering an IBM System Storage DS8800. What is a key advantage of the DS8800()
第16题:
An IBM Business Partner has sold a DS5020 and new IBM SAN switches to replace a customer EMC storage infrastructure. The customer dissatisfaction has arisen during the installation because according to the DS5020 interoperability matrix, two HP Proliant servers running Exchange have FC HBAs that are not supported. Which of the following is the most probable cause of the customer dissatisfaction()
第17题:
A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000. Where can the sales representative find this information()
第18题:
A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers. What is the best document the Business Partner can suggest to accomplish this requirement()
第19题:
An IBM Business Partner sells an IBM System Storage DS8700 to a customer. Who is responsible for the installation and set up of the storage server()
第20题:
A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()
第21题:
the IBM System Storage DS8000 Interoperability Matrix
the IBM System Storage DS8000 Introduction and Planning Guide
the IBM System Storage DS8000 Host System Attachment Guide
the IBM System Storage DS8000 User’s Guide
第22题:
8 drive sets of 300 GB drives
4 drive sets of 300 GB drives
14 drive sets of 146 GB drives
18 drive sets of 146 GB drives
第23题:
the production environment does not require an outage
the production environment requires an outage to install the SVC
the production environment requires an outage to install the DS8700
the production environment requires an outage to remove the EMC systems