rmdev -Rdl fcs0
rmdev -cdl fcs0
rmdev -cdl fscsi0
rmdev -Rdl fscsi0
第1题:
A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated. The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage. Each system has the following: ? 2 integrated network ports ? 2 fibre channel adapter cards ? 1 power supply and redundant cooling ? HACMP v5.1 In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()
第2题:
An administrator has added a new device to a system and wants to determine if it has been correctly added to the ODM database. Which command would the system administrator use?()
第3题:
()命令删除光纤卡fsc0。
第4题:
A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced. Which command should an administrator use to remove the card device and attached child devices?()
第5题:
A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced. Which command should an administrator use to remove the card device and attached child devices?()
第6题:
A system administrator has determined a root mirrored disk, hdisk1, needs to be replaced. The root volume has been unmirrored. What is the next step to remove the disk drive?()
第7题:
Company.com is adding a new I/O drawer to an existing p5-570 with four LPARs and wants to re-balance the network cards in the I/O drawers. What is the best way to accomplish this?()
第8题:
Add the devices as virtual adapters to a VIO server first,then add the I/O drawer and create the shared ethernet adapters
Power down the partitions,run the diag a command when the system is brought back up and reconfigure the network cards
Use the rmdev command to remove the devices,shut down the partitions and move the cads,then run the cfgmgr command after reboot
Detach the network cards,run rmdev on the devices and then dynamically reassign theadapters to the partitions and reconfigure
第9题:
rmdev -Rdl fcs0
rmdev -cdl fcs0
rmdev -cdl fscsi0
rmdev -Rdl fscsi0
第10题:
reducevg, rmdev, syncvg
rmlvcopy, exportvg, rmdev
rmlvcopy, reducevg, rmdev
No action is required since SSA is a Hot Swap device and is mirrored
第11题:
rmdev hdsik12 vscsi0rmdev ? hdsik12 ? vscsi0
rmpath hdisk12 vscsi0rmpath ? hdisk12 ? vscsi0
chpath hdisk12 vscsi0 -dchpath ? hdisk12 ? vscsi0 -d
varyoffvg vg01; rmdev hdisk12 vscsi0 varyoffvg vg01; rmdev ? hdisk12 ? vscsi0
第12题:
odmget
odmadd
odmshow
odmcreate
第13题:
A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem. If fcs1 has failed, what is the correct procedure to rectify this problem? ()
第14题:
A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()
第15题:
An SSA disk that is part of the mirrored volume group needs to be replaced. Which of the following procedures should be performed before the disk is physically able to be replaced?()
第16题:
An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()
第17题:
A graphics card has been added and the system rebooted. When running the lsdev-Cc adapter, the graphics card is not listed in the output. Which of the following actions should be performed?()
第18题:
There is the possibility that hdisk1 in the root volume group is going bad. A decision has been made to replace the disk. After saving all of the data from the disk and unmounting any filesystems on the disk, which of the following commands should be run before removing the disk from the system?()
第19题:
chgv -a n hdisk rootvg; rmdev -1 hdisk1 -d
rmdev -1 hdisk1 -d; reducevg -df rootvg hdisk1
reducevg -df rootvg hdisk1; rmdev -1 hdisk1 -d
reducevg -df rootvg hdisk1; rmdev -1 hdisk1
第20题:
Reboot system sing the mkdev -l command.
Install device support suing the cfgmgr -i command.
Use the SMIT console to redirect the console.
Use SMIT devices and choose the correct adapter.
第21题:
Using ’diagmenu’ command, set fcs1 to Defined.
Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.
Using ’diagmenu’ command, set the fcs1 state to Defined
Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined
第22题:
rmdev -Rdl fcs0
rmdev -cdl fcs0
rmdev -cdl fscsi0
rmdev -Rdl fscsi0
第23题:
On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name
On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name
On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
第24题:
chvg
rmdev
reducevg
exportvg