第1题:
Best practices would have no single point of failure between mirrored resources. In setting up virtual, internal boot disks for two client LPARs, how would this be accomplished?()
第2题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第3题:
A customer is configuring Live Partition Mobility on two POWER6-based servers, Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()
第4题:
Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()
第5题:
When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers, which of the following attributes must have a different value on both VIO servers?()
第6题:
Run cfgdev on the VIO server and re-run the mkvdev command.
Run chdev -a sea_enable=yes on the physical Ethernet adapter.
Remove and re-add the virtual Ethernet adapter.
Remove the IP address from the physical adapter and re-run the mkvdev command.
第7题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers.
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第8题:
A VIO server requires a dedicated LHEA port.
There is a limit of 32 LPARs per virtual LAN.
Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.
Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.
第9题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第10题:
Etherchannel and trunking
Network Interface Backup and Etherchannel
Shared Ethernet Adapter (SEA) Failover and Etherchannel
Network Interface Backup and Shared Ethernet Adapter failover
第11题:
IBM Director connection
Dynamic LPAR Resource Manager (DLRM)
Barrier Synchronization Register Device (BSR)
Virtual Asynchronous Services Interface (VASI)
第12题:
algorithm = failover
algorithm = round_robin
reserve_policy = no_reserve
reserve_policy = single_path
第13题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第14题:
The administrator of a Power 595 server is required to concurrently host LPARs for two different customers. Both customers’ LPARs have the same VLAN ID and subnet range, but their traffic must be isolated from each other. Which feature within the system would provide this functionality?()
第15题:
A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
第16题:
Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()
第17题:
When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()
第18题:
802.1Q
Virtual switch
Logical Host Ethernet (LHE) Adapter
Shared Ethernet Adapter (SEA) Trunking
第19题:
A virtual Ethernet adapter can only connect to other partitions within the same system.
A virtual Ethernet adapter needs to be connected to an external VLAN capable switch to be able to communicate with other partitions on the same system.
A partition can support an unlimited number of virtual Ethernet devices.
A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the trunk flag set
第20题:
ImplementPowerHA SystemMirror on both VIO servers.
ConfigureEtherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第21题:
HA Mode
Trunk priority
Control Channel
Default VLAN ID
第22题:
Have one VIO server with striped disks for all LPARs
Have one VIO server with mirrored disks for all LPARs
Have two VIO servers with each LPAR accessing both VIO servers
Have two VIO servers with each LPAR accessing a different VIO server
第23题:
Configure a Shared Ethernet Adapter on the Virtual I/O Server.
Use the same virtual LAN ID on each LPAR.
Set up IP routing through an LPAR on each system.
Set up an IP firewall through an LPAR on each system.
第24题:
mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1
mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1
mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1