itgle.com

单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the followin

题目
单选题
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()
A

Youcan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch

B

Using blade servers with the NPIV switch will require morefibre ports on the external fibre switch

C

Storage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.

D

The NPIV switch will count against the number of domains in a fabric


相似考题
更多“单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the followin”相关问题
  • 第1题:

    A customer is very concerned about maintaining a competitive advantage through the use of state-of-the-art technology.  Assuming all solutions meet the customer’s technical requirements, which solution should the IBM team propose to maximize customer satisfaction?()

    • A、p690 with Dynamic LPAR
    • B、Grid of SP switch-attached p5-550s
    • C、p690 with Advanced POWER Virtualization
    • D、p5-570 with Advanced POWER Virtualization

    正确答案:D

  • 第2题:

    A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000.  What is required for the customer to be able to perform this?()

    • A、Fibre Channel Expansion Card for each Blade Server
    • B、cKVM Card for each Blade Server
    • C、iSCSI Expansion Card for each Blade Server
    • D、4Gb Modular Flash Drive

    正确答案:C

  • 第3题:

    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()

    • A、You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch 
    • B、Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch 
    • C、Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch
    • D、The NPIV switch will count against the number of domains in a fabric

    正确答案:C

  • 第4题:

    The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()

    • A、IBM DS8700 
    • B、IBM N6040 
    • C、IBM Storwize V7000 
    • D、IBM XIV Storage System

    正确答案:B

  • 第5题:

    A customer is considering BladeCenter H and S chassis. Which of the following is a reason to implement BladeCenter H?()

    • A、Support for10Gb internal network
    • B、Support for SSD
    • C、Support for integrated disk drives
    • D、Support for8Gb FC Switch Modules

    正确答案:A

  • 第6题:

    A customer has Symantec NetBackup installed and is concerned about restore times for a line ofbusiness server. Which IBM Tivoli Storage Manager feature addresses this customer’s concerns?()

    • A、migration
    • B、collocation
    • C、compression
    • D、subfile backup

    正确答案:B

  • 第7题:

    单选题
    A new customer wants to install a Power 750 in a warehouse location that has no local staff to support it. They are concerned about hardware support and would like to have the system notify IBM service if there is an issue.Which actions will address the customer concern?()
    A

    Enable automatic problem reporting from smit

    B

    Use IVM to enable console mirroring to IBM Remote Support.

    C

    Use the HMC to enable reporting through Electronic Service Agent.

    D

    Enable Automatic Problem Reporting in ASMI using he embedded modem on the FSP.


    正确答案: A
    解析: 暂无解析

  • 第8题:

    单选题
    A medical customer wants to deploy around 8TB integrated storage on a BladeCenter.Which of the following should be discussed with this customer?()
    A

    SATA internal disks

    B

    iSCSI

    C

    Solid State Storage

    D

    SAS Internal Disk


    正确答案: B
    解析: 暂无解析

  • 第9题:

    单选题
    A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()
    A

    4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server 

    B

    Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module 

    C

    Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module 

    D

    Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server


    正确答案: C
    解析: 暂无解析

  • 第10题:

    单选题
    A customer has Symantec NetBackup installed and is concerned about restore times for a line ofbusiness server. Which IBM Tivoli Storage Manager feature addresses this customer’s concerns?()
    A

    migration

    B

    collocation

    C

    compression

    D

    subfile backup


    正确答案: A
    解析: 暂无解析

  • 第11题:

    单选题
    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()
    A

    You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.

    B

    Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.

    C

    The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.

    D

    The blade servers do not work with the Optical Pass-Thru Module.


    正确答案: B
    解析: 暂无解析

  • 第12题:

    单选题
    A customer is very concerned about maintaining a competitive advantage through the use of state-of-the-art technology.  Assuming all solutions meet the customer’s technical requirements, which solution should the IBM team propose to maximize customer satisfaction?()
    A

    p690 with Dynamic LPAR

    B

    Grid of SP switch-attached p5-550s

    C

    p690 with Advanced POWER Virtualization

    D

    p5-570 with Advanced POWER Virtualization


    正确答案: C
    解析: 暂无解析

  • 第13题:

    An existing IBM customer has some iSeries servers in their environment.  The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications.  The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms.  Which of the following will accomplish this?()

    • A、Share the data over the Ethernet LAN.
    • B、Install the IXA Adapter in the iSeries server.
    • C、Install the IXA Adapter in the xSeries server.
    • D、Attach both servers to an IXS switch.

    正确答案:C

  • 第14题:

    While installing a new IBM System Storage DS5100 into a customer’s data center, it is discoveredthat the customer does not have enough available Fibre Channel ports on their switches. Which ofthe following should have been used to avoid this situation?()

    • A、IBM DS5000 Cabling Tool
    • B、IBM e-Configurator Tool
    • C、IBM Pre-Installation TDA Checklist
    • D、IBM Standalone Solutions Configuration Tool

    正确答案:C

  • 第15题:

    A medical customer wants to deploy around 8TB integrated storage on a BladeCenter.Which of the following should be discussed with this customer?()

    • A、SATA internal disks
    • B、iSCSI
    • C、Solid State Storage
    • D、SAS Internal Disk

    正确答案:A

  • 第16题:

    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()

    • A、You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.
    • B、Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.
    • C、The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.
    • D、The blade servers do not work with the Optical Pass-Thru Module.

    正确答案:B

  • 第17题:

    A new customer wants to install a Power 750 in a warehouse location that has no local staff to support it. They are concerned about hardware support and would like to have the system notify IBM service if there is an issue.Which actions will address the customer concern?()

    • A、Enable automatic problem reporting from smit
    • B、Use IVM to enable console mirroring to IBM Remote Support.
    • C、Use the HMC to enable reporting through Electronic Service Agent.
    • D、Enable Automatic Problem Reporting in ASMI using he embedded modem on the FSP.

    正确答案:C

  • 第18题:

    单选题
    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()
    A

    You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch 

    B

    Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch 

    C

    Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch

    D

    The NPIV switch will count against the number of domains in a fabric


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    A customer wants to realize a server-based computing scenario for trading floor applications with IBM BladeCenter. The customer expects the solution to offer high security and manageability, while delivering hardware-based graphics compression and full USB capability.  Is this possible?()
    A

    A

    B

    B

    C

    C

    D

    D


    正确答案: D
    解析: 暂无解析

  • 第20题:

    单选题
    A customer is considering BladeCenter H and S chassis. Which of the following is a reason to implement BladeCenter H?()
    A

    Support for10Gb internal network

    B

    Support for SSD

    C

    Support for integrated disk drives

    D

    Support for8Gb FC Switch Modules


    正确答案: C
    解析: 暂无解析

  • 第21题:

    单选题
    A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack.  Which IBM BladeCenter Chassis should be recommended? ()
    A

    BladeCenter E

    B

    BladeCenter H

    C

    BladeCenter T

    D

    BladeCenter HT


    正确答案: D
    解析: 暂无解析

  • 第22题:

    单选题
    A manufacturing customer has an IBM BladeCenter H chassis with four, HX5 with MAX5 4-socket blades installed. Each blade has the optional Fibre Channel Expansion card. The customer wants redundancy and is going to install the following configuration:  (1)two Brocade 20-Port SAN Switch Modules  (2)two Nortel Networks 1/10 GB Uplink ESM  (3)a redundant AMM  What is the minimum number of power supplies needed for this configuration to have full redundancy?()
    A

    4

    B

    3

    C

    2

    D

    8


    正确答案: D
    解析: 暂无解析

  • 第23题:

    单选题
    A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000.  What is required for the customer to be able to perform this?()
    A

    Fibre Channel Expansion Card for each Blade Server

    B

    cKVM Card for each Blade Server

    C

    iSCSI Expansion Card for each Blade Server

    D

    4Gb Modular Flash Drive


    正确答案: B
    解析: 暂无解析